Qty.10 Andrew CommScope 7/8" HELIAX® AVA5-50 N-Female Connectors

CommScope® / Andrew

  • $450.00
    Unit price per 
Tax included.

Only 1 left!

ITEM# S-042722D

 

78EZNF Type N Female EZfit® for 7/8 inch FXL-780, AVA5-50, and AVA5-50FX cable. Sold in lots of 10.

 

Specifications

Product Classification

Product Type Wireless and radiating connector
Product Brand EZfit®
Product Series AVA5-50 | AVA5-50FX | AVA5RK-50
Ordering Note CommScope® non-standard product

General Specifications

Body Style Straight
Cable Family AVA5-50 | AVA5-50FX | FXL-780
Inner Contact Attachment Method Captivated
Inner Contact Plating Silver
Interface N Female
Mounting Angle Straight
Outer Contact Attachment Method Clamp
Outer Contact Plating Trimetal
Pressurizable No

Dimensions

Length 52.07 mm | 2.050 in
Diameter 37.08 mm | 1.460 in
Nominal Size 7/8 in

Electrical Specifications

3rd Order IMD at Frequency -116 dBm @ 1800 MHz
3rd Order IMD Test Method Two +43 dBm carriers
Insertion Loss, typical 0.05 dB
Cable Impedance 50 ohm
Connector Impedance 50 ohm
dc Test Voltage 2000 V
Inner Contact Resistance, maximum 2 mOhm
Insulation Resistance, minimum 5000 mOhm
Operating Frequency Band 0 – 5000 MHz
Outer Contact Resistance, maximum 0.3 mOhm
Peak Power, maximum 10 kW
RF Operating Voltage, maximum (vrms) 707 V

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
50–1000 MHz 1.020 40.09
1000–1900 MHz 1.025 38.17
1900–2200 MHz 1.041 33.94
2200–2700 MHz 1.058 31.00
2700–3600 MHz 1.065 30.04
3600–5000 MHz 1.106 25.96

Mechanical Specifications

Attachment Durability 25 cycles
Connector Retention Tensile Force 1334.47 N | 300.000 lbf
Connector Retention Torque 8.14 N-m | 72.001 in lb
Insertion Force 66.72 N | 15.000 lbf
Insertion Force Method MIL-C-39012C-3.12, 4.6.9
Interface Durability 500 cycles
Interface Durability Method IEC 61169-16:9.5
Mechanical Shock Test Method MIL-STD-202F, Method 213B, Test Condition C

Environmental Specifications

Operating Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A
Immersion Depth 1 m
Immersion Test Mating Mated
Immersion Test Method IEC 60529:2001, IP68
Moisture Resistance Test Method MIL-STD-202F, Method 106F
Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method IEC 60068-2-6
Water Jetting Test Mating Mated
Water Jetting Test Method IEC 60529:2001, IP66

Packaging and Weights

Weight, net 135.54 g | 0.299 lb

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015  Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance